Stop cause word

Bit-packed word indicating why the drive stopped

*

0

Stop asserted or Run de-asserted (negated)

1

Jog de-asserted for more than 1 second

2

Internal stop request

3

Current limit stop

4

Ramp stop

5

Coast/DB stop

6

Fault stop or self-tuning completed

7

Customer interlock opened

8

Coast/DB interlock opened

9

Main contactor opened

10 – 15

Reserved

27

Process Error Parameter Number

Indicates the parameter number that caused a
processing error.

-1 = No parameter processing error.

28

0

NETW

CONNECT

TYPE

(P.910)

AutoMax network connection type

0=

BASIC

; 1=

FULL

8

NETW

REGISTER

MAP

SEL

(P.914)

Network register map selected

0=

ORIGINAL

; 1=

ALTERNATE

29 to 30

Reserved

31

REGULATOR

SW

VERSION

(P.794)

Regulator board software version

*

Before examining this register, check the drive status word (Drop_1, register 0) to determine if the drive is presently running or jogging. If neither of these bits is set to

ON

(1), then the stop

cause word can be examined to determine why the drive last stopped. If all the defined bits in the stop cause word are false, the drive is either running, jogging, or has not been started since
the last power-up.

Table 6.4 – FlexPak 3000 Alternate Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Tunable, Configurable, and Status Data (Drive Output Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Tunable, configurable, and status data are updated by the regulator approximately every 600 msec.