Cross Reference of Parameter Name to Drop and Register (FlexPak 3000 Original Map)

A-3

IET

(

OVERCURRENT

) (F00001)

1

10

8

In current limit

1

0

9

INERTIA

COMP

SELECT

(P.221)

2

56

Internal stop request

4

22

2

IR

COMPENSATION

(P.206)

1

55

3

21

Jog

1

32

3

JOG

ACCEL

/

DECEL

TIME

(P.013)

2

15

2

40

Jog de-asserted < 1 second

4

22

1

JOG

SPEED

1 (P.012)

1

53

2

14

Last alarm

1

14

Level Dectector Outputs

4

21

0& 1

LEVEL

DETECT

1

DELAY

(P.604)

4

37

LEVEL

DETECT

1

SELECT

(P.602)

4

60

LEVEL

DETECT

1

THRESH

(P.603)

4

36

LEVEL

DETECT

2

DELAY

(P.607)

4

39

LEVEL

DETECT

2

SELECT

(P.605)

4

61

LEVEL

DETECT

2

THRESH

(P.606)

4

38

Main contactor opened

4

22

9

MAXIMUM

CURRENT

(P.007)

3

12

3

58

MAXIMUM

SPEED

(P.004)

1

19

1

43

Memory save

1

32

11

MINIMUM

SPEED

(P.003)

1

18

1

42

MOTOR

BRUSH

WEAR

LOW

(A00001)

1

13

0

MOTOR

HOT

FLD

AMPS

(P.510)

3

55

MOTOR

RATED

ARM

AMPS

(P.008)

3

13

3

59

MOTOR

RATED

ARM

VOLTS

(P.009)

3

14

3

60

MOTOR

THERMOSTAT

TRIP

(F00008)

1

10

4

NEG

CURRENT

LIM

SEL

(P.224)

2

58

NEGATIVE

CURRENT

LIM

(P.006)

1

21

1

45

Table A.1 – Cross Reference of Parameter Name to Drop and

Register (FlexPak 3000 Original Map) (Continued)

Parameter Name (No.)

Drop

Register

Bit

NETW

COMM

LOSS

SELECT

(P.901)

1

29

1

57

NETW

CONNECT

TYPE

(P.910)

1

28

1

62

NETW

IN

REG

1 (P.905)

1

34

NETW

IN

REG

2 (P.906)

1

35

NETW

IN

REG

3 (P.907)

1

36

NETW

OUT

REG

1

SELECT

(P.902)

1

58

NETW

OUT

REG

2

SELECT

(P.903)

1

59

NETW

OUT

REG

3

SELECT

(P.904)

1

60

NETWORK

COMMUNICATION

TIMEOUT

(F00013)

1

10

14

Network Output Register 1

1

7

Network Output Register 2

1

8

Network Output Register 3

1

9

Network Reference

1

33

NOMINAL

AC

LINE

FREQ

(P.306)

4

23

4

62

NOMINAL

AC

LINE

VOLTS

(P.307)

4

24

4

63

NORMALIZED

INERTIA

(P.222)

2

33

OCL

FEEDBACK

SELECT

(P.804)

2

60

OCL

LEADLAG

LOW

FREQ

(P.806)

2

38

OCL

LEADLAG

RATIO

(P.807)

2

39

OCL

LEADLAG

SELECT

(P.805)

2

37

OCL

OUTPUT

(P.848)

1

21

2

12

OCL

PI

LEAD

FREQ

(P.809)

2

52

OCL

PI

NEGATIVE

LIMIT

(P.811)

2

54

OCL

PI

POSITIVE

LIMIT

(P.810)

2

53

OCL

PI

PROP

GAIN

(P.808)

2

51

OCL

RAMP

OUTPUT

(P.846)

2

11

OCL

REF

RAMP

TIME

(P.802)

2

35

OCL

REF

REGISTER

(P.801)

2

34

OCL

REF

ROUNDING

(P.803)

2

36

OCL

REFERENCE

SELECT

(P.800)

2

59

OCL

TRIM

RANGE

(P.812)

2

55

Table A.1 – Cross Reference of Parameter Name to Drop and

Register (FlexPak 3000 Original Map) (Continued)

Parameter Name (No.)

Drop

Register

Bit