50 to 53 – Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 43

Advertising
background image

F

lex
Pak

3000 Drives

: O
rig

inal Regist

er
M

a

p

5-

13

39

FLD

WEAKEN

LEAD

FREQ

(P.520)

PI

block lead break frequency of the field control loop’s

armature voltage regulator

radians/second * 100

40

ANALOG

TACH

GAIN

ADJ

(P.201)

Scales analog tachometer feedback signal

gain * 1000

41

ANALOG

TACH

ZERO

ADJ

(P.202)

Offset from analog tachometer feedback signal

42

ARM

VOLTAGE

GAIN

ADJ

(P.204)

Scales the armature voltage signal

gain * 1000

43

ARM

VOLTAGE

ZERO

ADJ

(P.205)

Offset removed from armature voltage feedback

44

SPD

LEADLAG

RATIO

(P.213)

Specifies the ratio between low and high break
frequencies of speed feedback lead/lag block

45

SPD

LEADLAG

LOW

FREQ

(P.214)

Low break freq. of the speed feedback lead/lag block

radians/second * 100

46

SPD

LOOP

LAG

FREQ

(P.215)

Lag break freq. for the speed loop forward path lag block radians/second * 100

47

SPD

LEADLAG

SELECT

(P.216)

Speed/voltage loop lead/lag block select

0=

LEAD

/

LAG

; 1=

BYPASS

; 2 =

LAG

/

LEAD

48

SPD

LOOP

LAG

BYPASS

(P.217)

Speed/voltage loop lag block bypass

0=

OFF

(not bypassed); 1=

ON

(bypassed)

49

CML

FEEDBACK

GAIN

ADJ

(P.300)

Current minor loop feedback gain adjust

gain * 1000

50 to 53

Reserved

Table 5.14 – FlexPak 3000 Original Register Map, Drop_3: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

54

AUTO

REFERENCE

SELECT

(P.103)

Selects the type of auto reference

0=

ANALOG

; 1=

FREQUENCY

IN

55

MOTOR

HOT

FLD

AMPS

(P.510)

Rated hot field amps from motor nameplate

amps * 100

56

FIELD

LOSS

THRESHOLD

(P.512)

Field current level at which a field loss fault is generated

% of

MOTOR

HOT

FLD

AMPS

(P.510)

57

FIELD

AUTO

WEAKEN

(P.517)

Enables or disables automatic field weakening

0=

DISABLED

; 1=

ENABLED

58

MAXIMUM

CURRENT

(P.007)

Highest amount of current, either positive or negative

% of

MOTOR

RATED

ARM

AMPS

(P.008)

59

MOTOR

RATED

ARM

AMPS

(P.008)

Rated armature current from motor nameplate

amps * 10

60

MOTOR

RATED

ARM

VOLTS

(P.009)

Rated armature voltage from motor nameplate

volts DC

61

ANLG

TACH

VOLTS

/1000 (P.203)

Analog tachometer scaling from tachometer nameplate
in volts per 1000

RPM

volts * 10

62

PULSE

TACH

PPR

(P.207)

Pulses per revolution from pulse encoder nameplate

63

PULSE

TACH

QUADRATURE

(P.208)

Enables or disables pulse encoder quadrature

0=

OFF

; 1=

ON

(quad decode)

Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.

Table 5.13 – FlexPak 3000 Original Register Map, Drop_3: Master Write Registers, FULL Connection. Tunable Data (Drive Input Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Tunable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit = 1.