Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 61

Advertising
background image

F

lex
Pak

3000 Drives

: Alt
e

rnat
e Regist

er
M

a

p

6-

13

45

ANLG

MAN

REF

ZERO

ADJ

(P.105)

Offset removed from the analog manual reference signal

46

TRIM

REFERENCE

SELECT

(P.108)

Trim reference selection

0=

REGISTER

; 1=

ANALOG

MANUAL

; 2=

ANALOG

IN

1; 3=

NETW

IN

REG

1; 4=

NETW

IN

REG

2; 5=

NETW

IN

REG

3; 6=

ANALOG

IN

2

47

TRIM

MODE

SELECT

(P.110)

Type of trim mode selected

0=

NO

TRIM

; 1=

INCREMENTAL

; 2=

PROPORTIONAL

48

AUTO

MODE

MIN

BYPASS

(P.111)

Disables minimum speed limit while in auto mode

0=

OFF

;1=

ON

(min speed bypassed)

49

AUTO

MODE

RAMP

BYPASS

(P.112) Bypasses speed loop S-curve block when drive in auto

0=

OFF

;1=

ON

(rate limit bypassed)

50

STOP

SPEED

THRESHOLD

(P.113)

Speed threshold at which the main contactor will open during a controlled stop

51

CML

REF

RATE

LIMIT

(P.303)

Min time for

CML

ref to go from zero to

MAXIMUM

CURRENT

milliseconds

52

JOG

SPEED

1 (P.012)

Operating speed while jogging

RPM

53

STOP

MODE

SELECT

(P.114)

Selects how drive responds to a normal stop command

0=

RAMP

; 1=

COAST

/

DB

; 2=

CURRENT

LIMIT

54

IR

COMPENSATION

(P.206)

Armature voltage loss compensation

%

55

OCL

TRIM

RANGE

(P.812)

Trim range for the

OCL

% * 10

Table 6.11 – FlexPak 3000 Alternate Register Map, Drop_2: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data)

Register Bit Parameter Name (Number)

Description

Settings

32

SPD

LOOP

PI

INIT

SEL

Source for the initial value of the speed loop

PI

block

0=

ZERO

(default); 1=

SPD

LOOP

PI

INIT

VAL

(Drop_1, register

39); 2=

ANALOG

MAN

TRIM

REF

(P.194)

*

56

INERTIA

COMP

SELECT

(P.221)

Source of inertia compensation

0=

NONE

; 1=

INTERNAL

; 2=

ANALOG

IN

1; 3=

ANALOG

IN

2;

4=

NETW

IN

REG

1 (P.905); 5=

NETW

IN

REG

2 (P.906); 6=

NETW

IN

REG

3 (P.907)

57

POS

CURRENT

LIM

SEL

(P.223)

Selects positive current limit source

0=

REGISTER

; 1=

ANALOG

IN

1; 2=

ANALOG

IN

2; 3=

NETW

IN

REG

;

4=

NETW

IN

REG

2; 5=

NETW

IN

REG

3

58

NEG

CURRENT

LIM

SEL

(P.224)

Selects negative current limit source

59

OCL

REFERENCE

SELECT

(P.800)

Selects

OCL

reference source

0=

REGISTER

; 1=

ANALOG

IN

1; 2=

ANALOG

IN

; 3=

FREQUENCY

IN

;

4=

NETW

IN

REG

1; 5=

NETW

IN

REG

2; 6=

NETW

IN

REG

3

60

OCL

FEEDBACK

SELECT

(P.804)

Source of

OCL

feedback

0=

NONE

; 1=

CML

FEEDBACK

; 2=

ANALOG

IN

1; 3=

ANALOG

IN

2;

4=

SPEED

LOOP

OUTPUT

; 5=

ANALOG

AUTO

REFERENCE

; 6=

NETW

IN

REG

1; 7=

NETW

IN

REG

2; 8=

NETW

IN

REG

3

61

TOP

SPEED

(P.011)

Highest running speed of motor

RPM

62

REVERSE

DISABLE

(P.015)

Prevents speed/voltage loop ref. from going negative 0=

OFF

(bipolar ref); 1=

ON

(positive ref)

Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.

Table 6.10 – FlexPak 3000 Alternate Register Map, Drop_2: Master Write Registers, FULL Connection. Tunable Data (Drive Input Data) (Continued)

Register Bit Parameter Name (Number)

Description

Settings

Tunable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit = 1.