11 to 16 – Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 74

Advertising
background image

7-

6

Aut

o

Max

Net

w

or

k Comm

unicat

ion
O

p

tion
B

oard

11

TB Tension On

12

TB Current Memory

13

TB Underwind

14

TB Slack Take Up

15

Level Det1 Output

2

SPD

LOOP

REFERENCE

(P.295)

Final speed/voltage loop reference value

3

SPD

LOOP

FEEDBACK

(P.296)

Final speed/voltage loop feedback value after all scaling

4

SPD

LOOP

OUTPUT

(P.299)

Speed loop

PI

block output value

4095 at

MAXIMUM

CURRENT

(P.007)

5

ARMATURE

VOLTAGE

(P.289)

Armature voltage feedback value

4095 at

MOTOR

RATED

ARM

VOLTS

(P.009)

6

CML

REFERENCE

(P.196)

Amplitude-and rate-limited value of the selected

CML

reference

7

Average

CML

feedback

CML

feedback average over eight

CML

scans

4095 at

MAXIMUM

CURRENT

(P.007)

8

Network Output Register 1

Value of the parameter selected by

NETW

OUT

REG

1

SELECT

(P.902)

If no valid parameter value selected,
0=

MOTOR

SPEED

IN

RPM

9

Network Output Register 2

Value of the parameter selected by

NETW

OUT

REG

2

SELECT

(P.903)

If no valid parameter value selected,
0=armature voltage in volts

10

Network Output Register 3

Value of the parameter selected by

NETW

OUT

REG

3

SELECT

(P.904)

If no valid parameter value selected,
0=armature current in amps*10 or amps

11 to 16

Tunable, Configurable and Status Data

See table 7.4 on page 7-7.

17

LINE

SPEED

(P.188)

Analog reference value output by the drive

18

DIAMETER

/

TAPER

IN

TP

(P.192)

Diameter/taper range input (TB 16, 17, 18) in counts
after gain and zero applied

DIAMETER

,

TAPER

RANGE

19

TENSION

SETPOINT

IN

(P.492)

Digital value of the tension setpoint input (TB 50, 51)
after gain and zero applied

20

TENSION

/

DANCER

FDBK

(P.493)

Digital value of the tension/dancer feedback input (TB
52, 53) after gain and zero applied

21

FREQ

IN

(P.491)

Frequency input value (terminals 39, 40, 41 on I/O
Expansion board) after all scaling

4095 at full scale

22

OCL

OUTPUT

(P.848)

Outer control loop output value

RPM

23

OCL

PARALLEL

OUT

(P.816)

Output of the selected outer control loop for parallel
mode

Table 7.3 – WebPak 3000 Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Runtime Signal Data (Drive Output Data) (Continued)

Register

Bit

Parameter Name (Number)

Description

Settings

Runtime signal data are updated by the regulator every 10 msec.

Advertising