H 5.18 de – Rockwell Automation FlexPak/WebPak 3000 DC Drive AutoMax Network Communication Board User Manual

Page 47

Advertising
background image

F

lex
Pak

3000 Drives

: O
rig

inal Regist

er
M

a

p

5-

17

Table 5.18 – FlexPak 3000 Original Register Map, Drop_4: Master Write Registers, FULL Connection. Configurable Data (Drive Input Data)

Register

Bit

Parameter Name (Number)

Description

Settings

48

DIG

OUT

1

SELECT

(P.409)

I/O Expansion kit digital output 1 source

0=

LEVEL

DETECT

1

OUTPUT

(P.648);

1=

LEVEL

DETECT

2

OUTPUT

(P.649);

2=in current limit; 3=drive ready;
4=

NETW COMM STATUS

(P.908);

5=bit 0 of Network Input Register 1;
6=bit 0 of Network Input Register 2;
7=bit 0 of Network Input Register 3

49

DIG

OUT

2

SELECT

(P.411)

I/O Expansion kit digital output 2 source)

0=

LEVEL

DETECT

1

OUTPUT

(P.648)

1=

LEVEL

DETECT

2

OUTPUT

(P.649)

2=in current limit; 3=drive ready
4=

NETW

COMM

STATUS

(P.908)

5=bit 1 of Network Input Register 1
6=bit 1 of Network Input Register 2
7=bit 1 of Network Input Register 3

50

0

DIG

OUT

1

CONTACT

TYP

(P.410)

I/O Expansion kit digital output 1 contact type

0=

NORMAL

OPEN

1=

NORMAL

CLOSED

1

DIG

OUT

2

CONTACT

TYP

(P.412)

I/O Expansion kit digital output 2 contact type

51

ANLG

IN

1

SIG

TYPE

(P.413)

I/O Expansion kit analog input 1 signal type

0=0-10 V; 1=±10 V; 2=4-20 mA; 3=10-50 mA

52

ANLG

OUT

1

SELECT

(P.418)

I/O Expansion kit analog output 1 source select

See “Settings for Analog and
Frequency Outputs” on page 4-8

53

ANLG

OUT

1

SIG

TYPE

(P.419)

I/O Expansion kit analog output 1 signal type

0=0- 10 V; 1=+/–10 V; 2=4-20 mA

54

ANLG

OUT

2

SELECT

(P.421)

I/O Expansion kit analog output source select

See “Settings for Analog and
Frequency Outputs” on page 4-8

55

FREQ

IN

ZERO

(P.423)

I/O Expansion kit minimum input frequency

kHz * 10

56

FREQ

IN

FULL

SCALE

(P.424)

I/O Expansion kit maximum input frequency

kHz * 10

57

FREQ

OUT

SELECT

(P.425)

I/O Expansion kit frequency output source select

See “Settings for Analog and
Frequency Outputs” on page 4-8

58

FREQ

OUT

ZERO

(P.426)

I/O Exp. kit frequency when freq. output signal is zero

kHz * 10

59

FREQ

OUT

FULL

SCALE

(P.427)

I/O Expansion kit frequency output at full scale

kHz * 10

60

LEVEL

DETECT

1

SELECT

(P.602)

Level detector 1 signal

0=

CML

FEEDBACK

; 1=

SPD

LOOP

FEEDBACK

2=

SPEED

RAMP

OUTPUT

; 3=

SPD

RAMP

INPUT

TP

; 4=

SPD

SOURCE

SELECT

OUT

61

LEVEL

DETECT

2

SELECT

(P.605)

Level detector 2 signal

62

NOMINAL

AC

LINE

FREQ

(P.306)

Nominal AC line frequency

Hz

63

NOMINAL

AC

LINE

VOLTS

(P.307)

Nominal AC line

RMS

voltage

volts

RMS

Configurable data are read by the regulator approximately every 600 msec when Tune/Config Input Enable bit=1 and the drive is not running or jogging.