Table 6.3 – FlexPak 3000 Alternate Register Map, Drop_1: Master Read Registers, BASIC and FULL Connections. Runtime Signal Data (Drive Output Data)

Register

Bit

Parameter Name (Number)

Description

Settings

0

Drive status word 1

Bit-packed word containing information on the present status of the drive

0

Drive ready

1

Drive running

2

Fault active

3

Drive jogging

4

Forward/Reverse command

0=forward; 1=reverse

5

Drive stopping

6

Tune/config input enable loopback

0=disabled; 1=enabled

7

Tune/config update synch flag loopback (master read)

8

Alarm active

9

In current limit

10

Parameter processing error

11

Level detector 1 output

12

Level detector 2 output

13–15

Reserved

1

Drive status word 2

Bit-packed word containing information on the present status of the drive

0

FN/DB status

1

Customer interlock

0=open; 1=closed

2

Terminal strip run

3

Terminal strip forward/reverse

4

Terminal strip jog

5

Terminal strip stop

6

Coast/DB interlock

0=open; 1=closed

7

Terminal strip fault reset

8

I/O Expansion kit digital input 1 (Preset speed select 1)

*

9

I/O Expansion kit digital input 2

(Preset speed select 2)

*

10

I/O Expansion kit digital input 3 (

MOP

decrement)

*

11

I/O Expansion kit digital input 4 (

MOP

increment)

*

12

I/O Expansion kit digital input 5 (

OCL

enable)

*

Runtime signal data are updated by the regulator every 5 msec, unless

FEEDBACK

SELECT

(P.200) is set to

ARMATURE

VOLT

, in which case the update time is 10 msec.