Metrohm tiamo 1.1 Manual User Manual

Page 52

Advertising
background image

24

General program functions

Identifier

Description

Commands

.BLV

Blank value of the sensor used for the command (for

ISE sensors only) or the blank value calculated during
calibration (for CAL LOOP Conc)

DET U, MET U, SET U,

STAT U, MEAS U, MEAS
Conc, CAL LOOP Conc,
DOS U

.BP{#}.DME

Difference in measured values for break point # (1...9) MET

.BP{#}.ERC

ERC or 1st derivative for break point # (1...9)

DET

.BP{#}.MEA

Measured value for break point # (1...9) in the units of
the measured value

DET, MET, MEAS (with-
out T/Flow)

.BP{#}.TEM

Temperature for break point # (1...9) in °C

DET, MET, MEAS (with-

out T/Flow)

.BP{#}.TIM

Time for break point # (1...9) in s

DET, MET, MEAS (with-
out T/Flow)

.BP{#}.VOL

Volume at break point # (1...9) in mL

DET, MET

.BSY

Command status; 1 = BUSY, HOLD or ERROR;
0 = READY; invalid (variable not present) = Com-
mand has never been started

All except START and
END

.CBY

Command status; 1 = conditioning active,
0 = conditioning not active

SET, KFT, KFC

.COK

Command status; 1 = conditioning criterion ful-
filled
, 0 = conditioning criterion not fulfilled

SET, KFT, KFC

.CONC

Concentration of the solution used for the command

DET, MET, SET, KFT,
STAT, ADD, DOS, LQH,
STDADD

.CYL

Cylinder volume of the exchange or dosing unit used
for the command

DET, MET, SET, KFT,
STAT, STDADD dos,

STDADD auto, ADD,
DOS, LQH, PREP,
EMPTY

.DBL

Total duration for processing the command in s

DET, MET, SET, KFT,
KFC, STAT, MEAS, CAL

MEAS, STDADD, DOS

.DRI

Current or last drift for drift correction in µL/min

SET, KFT, KFC

.DSC

Duration for processing all start conditions in s

DET, MET, SET, KFT,
STAT

.DTI

Time for the drift correction (time from start of titration

until end of command) in s

SET, KFT, KFC

.EGF

Last measured gas flow (measured value after proc-
essing the command) in mL/min

MEAS T/FLow

.EME

Final measured value (measured value after process-

ing the command) in the units of the measured value

DET, MET, SET, KFT,

KFC, STAT, MEAS, CAL
MEAS, STDADD, DOS

.ENP

Electrode zero point of the sensor used for the com-
mand (dimensionless for pH sensor or in mV for ISE
sensor) or the electrode zero point calculated from the

calibration (for CAL LOOP)

DET pH, DET U, MET
pH, MET U, SET pH,
SET U, STAT, MEAS pH,

MEAS U, MEAS T, MEAS
Conc, STDADD, CAL
LOOP, DOS

.EP{#}.DME

Difference in measured values for end point # (1...9)

MET