BEFORE YOU START

Always perform the system checkout procedures in
Group 05 and the System Diagnosis in Group 20
BEFORE making any tests in this group. These
procedures include any special tooling required to identify
a failure. Make the repair and perform the System
Checkout in Group 05 to be certain all failures are
solved.

;

KEY SWITCH TEST

Remove key switch
from machine. Test
terminals for continuity
using a continuity tester
or ohmmeter.

M37207 -UN-29AUG88

Key
Position

Continuity

OFF . . . . . . . . . NONE

RUN . . . . . . . . . B + A

START . . . . . . . B + A,

S

1

+ S

2

CONTINUITY: Key
switch OK.

NO CONTINUITY:
Replace key switch.

CIRCUIT BREAKER
TEST

M37397 -UN-25JAN90

NOTE: Machines:
316 (S.N. —362983)
318 (S.N. —364137)
420 (S.N. —360009)
shown.

Disconnect wires (A)
from circuit breaker.

Connect ohmmeter
across the circuit
breaker terminals.

ZERO RESISTANCE:
Circuit breaker OK.

RESISTANCE: Replace
circuit breaker.

MX,159024030,1 -19-16MAY95

MX,159024030,2 -19-16MAY95

MX,159024030,3 -19-16MAY95

Group 25