Receiver noise figure, Time-to-first-fix, Signal reacquisition – NavCom SF-3050 Rev.I User Manual

Page 134: Dynamics

Advertising
background image

SF-3050 GNSS Product User Guide

– Rev I

A-115

Receiver Noise Figure

17.0dB +0.5dB @ 290º Kelvin; 1Hz RBW

Time-to-First-Fix









Typical values measured per ION-STD 101

Signal Reacquisition

Dynamics

1

Restricted by USA export laws

2

Supported in software. The receiver hardware must be placed in a pressurized

environment for altitudes >12.2km (40,000 ft.)

Cold Start:

< 60 seconds

No valid Almanac or
Ephemeris data available

Warm Start:

< 50 seconds

Valid Almanac available (less
than one year old)

Hot Start:

< 20 seconds

Valid Ephemeris available
(less than 4 hours old)

< 30 second loss:

< 2 seconds

Acceleration:

Up to 6g

Speed:

< 515m/s

1

(1,000 knots)

Altitude:

< 18.3km

1,2

(60,000 ft)