6.4 Constant Settings

6 -9

6.4 Constant Settings

This section explains the user constant functions and settings.

6.4.1 User Constant Functions Table

A table of user constant functions is shown below. Change the constant set values depending on the operat-

ing specifications. Refer to 5.3.4 Control Constant Display Mode for setting methods.
Check that the following constant set values match the operating specifications.

D

Inverter settings

D

Machine specification settings

D

Sequence input signal settings

Table 6.3

User Constant Functions

No.

Item

Details

Related Constants

M5A

M5N

1

Inverter settings

Inverter Capacity Selection

C1-56

ON

ON

g

Motor Code Selection

C1-25

ON

ON

Orientation Control Method Selection

C1-39 bit 0

ON

ON

YENET1200 Card Encoder Selection

C1-58 bit 0

OFF

ON

RUN Mode Selection

C1-37 bits 1 and 0

ON

ON

2

Machine specification

tti

Rated Speed

C1-26

ON

ON

p

settings

Gear Ratio Settings

C1-27 to 29

ON

ON

3

Sequence input signal

settings

Sequence Input Signal Selections

C1-36 bits 1 and 0 (TLL/INC)

C1-36 bit 3 (SSC/SV)

C1-36 bit 4 (PPI/LM10)

C1-37 bit 2 (RDY/EMG2)

C1-40 bit 3 (ORT/NCORT)

ON

ON

Torque Limit Signal

C1-24 and C1-38, bit 2

ON

ON

12-bit Digital Reference Signal Selection

C1-36 bit 7 (Speed/position reference)

ON

OFF

4

Sequence output signal

tti

Zero-speed Detection Level (ZSPD)

C1-19

ON

ON

q

p

g

settings

Speed-agree Signal (AGR)

C1-20 and C1-38 bit 6

ON

ON

Speed Detection Signal (SDET)

C1-21 and C1-22

ON

ON

Torque Detection Signal (TDET)

C1-23 and C1-40 bit 2

ON

ON

5

Speed reference settings

Soft Start Time Setting

C1-10

ON

ON

p

g

Analog Speed Reference Adjustments

C1-11, C1-12, and C1-38 bit 5

ON

OFF

Digital Speed Reference Settings

C1-37 bits 7 and 6, and C1-41 to 48

ON

OFF

6

Analog output signal

tti

Speedometer Signal Adjustments

C1-16 and C1-54

ON

OFF

g

p

g

settings

Load Factor Meter Signal Adjustments

C1-17, C1-55, C1-18, C1-38 bits 1 and 0,

C1-38 bit 7, and C1-40 bit 4

ON

OFF

7

Speed control system

dj t

t

Speed Control Gain Adjustments

C1-01 to 04

ON

ON

p

y

adjustments

Motor Flux Lower Limit Level

C1-30

ON

ON

Torque Reference Filter Time Constant

C1-09

ON

ON

8

Servo mode settings

Analog Speed Reference Gain in Servo Mode

C1-38 bit 3, C1-40 bit 5, C1-49, and C1-50

ON

OFF

g

Servo Mode Flux and Base Speed Ratio

C1-31 to 34

ON

ON

Speed System Adjustment in Servo Mode

C1-05 to 08

ON

ON

9

Other settings

Zero-speed Braking Time

C1-35

ON

ON

g

Excessive Speed Deviation Protection Operation

Adjustments

C1-38 bit 4, and C1-40 bits 1 and 0

ON

ON

Load Fault Detection Selection

C1-40 bit 7

ON

ON

Fault Record Clear Selection

C1-57 bit 0

ON

ON

M5A: Stand-alone drive (analog speed reference settings); M5N: NC system (YENET1200 serial communica-

tions)

ON: Constant valid; OFF: Constant not valid (Not used.)

6

Advertising
This manual is related to the following products: