10.3 Magnetic Sensor Orientation Constants

10 -13

Table 10.3

Magnetic Sensor Orientation Constants (continued)

Con-

stant

No.

Name

Explanation

Change

*

1

Unit Standard

Setting

Upper

Limit/

Lower

Limit

C3 24

Orientation Control

Signal Selections 3
SEL-M3

*2

Orientation control parameters

S

Bits 5 and 4: Speed reference differential compensation gain

00: 10

01: 15

10: 20

11: 30

No

10000000

C3-24

11: 30

S

Bits 7 and 6: Flux level for positioning servo loop control

00: 100%

01: 80%

10: 60%

11: 40%

No

---

10000000

---

*1. Change (change during operation) column: Indicates whether the constant can be changed during inverter operation.

Yes: Constant can be changed during inverter operation; No: Constant cannot be changed during inverter operation