Yaskawa Varispeed 626M5 User Manual

Page 222

Advertising
background image

Specifications

14.2.2 Configuration

14 -18

Encoder

board

Encoder

connector

Cable connector

Main circuit

terminals

Fan power

supply ter-

minals

Cable connector

Z1 Z2 Z3

U V W

Fig 14.7 Terminal and Connector Arrangement

1

2

3

4

5

6

7

8

9

10

11

12

EL Connector (ELR-12V)

Number

Terminal

Number

Terminal

1

5 VDC

7

PC

2

0 V

8

:

PC

3

PA

9

FG (Frame Ground)

4

:

PA

10

SS (Shield)

5

PB

11

TS

6

:

PB

12

Fig 14.8 Encoder Connector

The common motor specifications are shown in the following table.

Table 14.13 Common Motor Specifications

Isolation

F type

Cooling Fan

Fan motor: Thermostat (auto resetting)

3-phase

200 V 50/60 Hz, 220 V 50/60 Hz, 230 V 60 Hz,

400 V 50/60 Hz, 440 V 50/60 Hz, 460 V 60 Hz

Overheating Protection

NTC Thermistor

Detector

Magnetic field encoder

Mounting Direction

Output shaft can be between horizontal to vertically down.

Bearing Lubrication

Grease

Color

Munsell N1.5

Ambient Temperature

0°C to 40°C (32°F to 104°F)

Humidity

95% max. (with no condensation)

Elevation

1000 m (3281 ft) max.

Insulation Voltage Resistance

1500 VAC for 1 min. (200 V Series)

1800 VAC for 1 min. (400 V Series)

Insulation Resistance

500 VDC, 10 MΩ min.

Conforming Standards

JIS, JEC

14

Advertising
This manual is related to the following products: