Yaskawa Varispeed 626M5 User Manual

Page 194

Advertising
background image

12 -10

Table 12.2

Inverter Faults (continued)

Fault No.

Name

Contents

Corrective Actions

Error Code

YENET1200
card fault

YENET1200 card fault

YENET1200
card RAM er-
ror

YENET1200 card memory (com-
mon RAM) error

YENET1200
card I/O fault
1

YENET1200 card data send/receive
error (initial handshake error)

Replace YENET1200 card.

---

YENET1200
card I/O fault
2

WDT error between control PCB
and YENET1200 card

YENET1200
card I/O fault
3

YENET1200 card interrupt signal
timeout error

Initial Origin
Detection Er-
ror (For IPM
motors only)

When the power is turned ON, a
phase-C signal cannot be detected
while detecting the initial origin.

S

Check the wiring of the C-phase

signal of the encoder.

S

Replace the encoder or motor.

S

Replace the control card.

fFff

Encoder Pulse
Number Error
(For IPM mo-
tors only)

The encoder pulse number per rota-
tion exceeded the correct value by
±10 pulses.

S

Check the wiring of the encoder

signal lines.

S

Check if the encoder signal line

is separated from the main cir-

cuit wiring and other power

cables.

S

Check if the motor and the In-

verter are properly grounded.

S

Check the encoder cable specifi-

cations. (Check if a shielded

twisted-pair cable is used.)

S

Replace the encoder.

fFff

Low

Speed

W i n d i n g
Overspeed Er-
ror (For IPM
motor only)

The motor speed exceeded the max.
speed for the low speed winding.

Check the external sequence to
verify that the winding change
point is correct.

fFff

12

Troubleshooting

Advertising