Yaskawa Varispeed 626M5 User Manual

Page 177

Advertising
background image

Control Constants

10 -10

Table 10.2

Encoder Orientation Constants (continued)

Con-

stant

No.

Name

Explanation

Change

*

1

Unit Standard

Setting

Upper

Limit/

Lower

Limit

C2 24

Orientation Con-
trol Signal Selec-
tions 3
SEL-E3

*2

Orientation control parameters
S

Bit 3: Speed control mode selection when positioning

*3

0: P control

1: PI control

S

Bits 5 and 4: Seed reference differential compensation gain

00: 10

01: 15

No

10000000

---

C2-24

01: 15

10: 20

11: 30

S

Bits 7 and 6: Flux level for positioning servo loop control

00: 100%

01: 80%

10: 60%

11: 40%

No

---

10000000

---

*1.

Change (change during operation) column: Indicates whether the constant can be changed during inverter operation.

Yes: Constant can be changed during inverter operation; No: Constant cannot be changed during inverter operation

*2. In signal selection descriptions, 0 stands for “

” and 1 for “

.”

*3. This function available in the following software.

VSM200XXX: VSM200095 or later

VSM2051XX: VSM205120 or later

VSM207XXX: VSM207051 or later