12.3 Inverter Faults

12 -11

Table 12.2

Inverter Faults (continued)

Fault No.

Name

Contents

Corrective Actions

Error Code

CPU built-in
A/D Convert-
er error

CPU built-in A/D Converter error

ffFf

Phase U A/D
Converter er-
ror

Phase U current detection A/D Con-
verter error

ffFf

Phase W A/D
Converter er-
ror

Phase W current detection A/D
Converter error

Replace the control PCB

ffFf

Control cir-
cuit I/O fault
1

Replace the control PCB.

ffFf

Control cir-
cuit I/O fault
2

Data transmission error between
CPUs.

ffFf

Control cir-
cuit I/O fault
3

ffFf

Motor code
selection error

Selected motor code (C1-25) does
not match Inverter capacity
(C1-56).

Check motor model, motor code
(C1-25), Inverter model, and In-
verter capacity selection (C1-56).

fffF

Motor code
unrecorded

Motor code set in C1-25 is not re-
corded.

S

Check motor model and motor

code (C1-25).

S

Check setting list for correct

PROM version of motor code

(C1-25).

fffF

Constant set-
ting range er-
ror

Memory (EEPROM) data exceeded
upper/lower limit.

S

Confirm

that

rated

speed

(C1-26) is within setting range.

S

Check control constants.

S

Replace the control PCB.

fffF

Orientation
Card mis-
match

Selected orientation bit does not
match Orientation Card.

S

Check Orientation Card model

and orientation selection signal

(bit 0 of C1-39).

S

Replace the Orientation Card.

fffF

Inverter ca-
pacity selec-
tion error

Selected Inverter capacity (C1-56)
does not match the Unit.

Check Inverter model and Invert-
er capacity selection (C1-56).

fffF

ROM error

Memory (PROM) error

ffff

EEPROM er-
ror 1

ffff

EEPROM er-
ror 2

Memory (EEPROM) error

Replace the control PCB.

ffff

EEPROM er-
ror 3

Memory (EEPROM) error

ffff

EEPROM er-
ror 4

ffff