Yaskawa Varispeed 626M5 User Manual

Page 179

Advertising
background image

Control Constants

10 -12

Table 10.3

Magnetic Sensor Orientation Constants (continued)

Con-

stant

No.

Name

Explanation

Change

*

1

Unit Standard

Setting

Upper

Limit/

Lower

Limit

C3 15

Starting Soft Start

Time

Soft start time for accelerating from stop to orientation speed. Use this

parameter to reduce gear noise at starting

No

ms

0

50

C3-15 Time

T

SFO

parameter to reduce gear noise at starting.

Acceleration rate is (500 min

−1

)/sec.

No

ms

0

0

C3 16

Flux Level

Flux level at completion of orientation. Motor noise and torque

h

i

i

fl

l

l

No

60

100

C3-16

φ

ORT

p

q

change in proportion to flux level.

No

---

60

15

C3 17

Orientation Speed

Reduction Coefficient

Reduction coefficient to set orientation speed in proportion to the

traveling angle for incremental positioning

No

0

32767

C3-17 Reduction Coefficient

K

SOR

traveling angle for incremental positioning.

No

---

0

0

C3 18 ---

---

C3-18 ---

---

---

---

---

---

C3 19 ---

---

C3-19 ---

---

---

---

---

---

C3 20

Sensor Signal Stan-

dardization Angle
θ

SEN

Angle for standardizing magnetic sensor signal detection sensitivity
θ

SEN

= 180°× Detection range (mm (inches)) ÷ Mounting radius ÷ π

Set 20.0 to θ

SEN when

θ

SEN

> 20.0.

F d

i

h k h

ifi i

f h

i

d

No

Deg

5 0

20.0

C3-20

For detection range, check the specifications of the magnetizer and

apply the values below:

MG-1378BS (15 mm (0.59 inches))

MG-1444S (7 mm (0.28 inches))

No

Deg.

5.0

5.0

C3 21 ---

---

C3-21 ---

---

---

---

---

---

C3 22

Orientation Control

Signal Selections 1
SEL-M1

*2

Control mode setting signals, e.g., for specifying the direction of

rotation in orientation control.

S

Bits 1 and 0: Positioning rotation direction

00: Automatically selected rotation direction

01: Same direction as the forward/reverse run signal

10: Fixed rotation direction

11: Automatically selected rotation direction

S

Bit 2: Selection for fixed rotation direction

0: Forward rotation of load shaft

1: Reverse rotation of load shaft

S

Bit 3: Stop position reference code

0: 12-bit binary

1: 3 digit BCD

No

11000000

C3-22

1: 3-digit BCD

S

Bit 4: Tuneup operation

0: Tuneup enabled

1: Tuneup disabled

S

Bit 5: Incremental positioning reference point

0: Previous stop reference position

1: Current stop position

S

Bit 6: Encoder selection

0: Load shaft encoder

1: Motor encoder

S

Bit 7: Rotation direction of motor and load shaft

0: Reverse

1: The same

No

---

11000000

---

C3 23

Orientation Control

Signal Selections 2
SEL-M2

*2

Dither signal pattern and gain

S

Bit 1: Dither signal pattern

0: 6 steps (83 Hz)

1: 2 steps (250 Hz)

S

Bits 4, 3, and 2: Dither signal level (H) (i.e., MGR and LGR are OFF)

000: 0.0% 011: 7.5% 110: 15.0%

No

00000000

C3-23

000: 0.0% 011: 7.5% 110: 15.0%

001: 2.5% 100: 10.0% 111: 17.5%

010: 5.0% 101: 12.5%

S

Bit 7, 6, and 5: Dither signal level (L) (i.e., MGR or LGR is ON)

000: 0% 011: 3%

110: 6%

001: 1% 100: 4% 111: 7%

010: 2% 101: 5%

No

---

00000000

---

10