Wiring

3.4.4 Sequence Input Signal Circuit (for Stand-alone Drive)

3 -32

3.4.4 Sequence Input Signal Circuit (for Stand-alone Drive)

Design the input signals in consideration of the following conditions.

D

The 12-bit digital reference signals into the Inverter’s 1CN connectors and the sequence input signals

into 6CN connectors can be 0 V, 24 V, or external common signals. The wiring of terminals varies with

the input method as shown below.

D

To select the external common method, prepare a 24-V (20 to 26 V) power supply for the input signal.

D

The 1CN common and 6CN common terminals are insulated. Therefore, it is possible to used the com-

mon terminals individually.

D

If a relay contact is used, the minimum contact capacity must be 5 mA at 30 V.

D

There will be a signal delay of approximately 5 ms due to the input filter.

0 V Common

+24 V Common

External Common

+24 V (or 0 V)

0 V (or +24 V)

EXTCOM

24VCOM
0VCOM

3.3kΩ

390Ω

EXTCOM

24VCOM

0VCOM

3.3kΩ

390Ω

EXTCOM

24VCOM

0VCOM

3.3kΩ

390Ω

Signal Name

Pin Number

Signal Name

1CN

6CN

EXTCOM

31

19, 20, 21

24VCOM

32

22, 23

0VCOM

33

24, 25

Fig 3.20