6.4.9 Motor Code Selection (MTR: C1-25)

6 -12

Precautions when Changing the Motor Code

After changing the Motor code, be sure to turn OFF the control power supply. Next, check that the Digital

Operator display is no longer lit, and then turn ON the power supply again. This operation will enable the new

Motor code.

Table 6.4

Motor Codes for Standard Spindle Motors

Voltage

Class

Motor

Inverter

Capacity

Inverter

Capacity

Selection

(C1-56)

Motor Model

Motor

Code

(C1-25)

Motor Max.

Speed

(min

−1

)

30 min./

Continuous

Rated Out-

put (kW)

Load Fac-

tor Meter

Max. Value

(%)

200 V

Standard

23P7

04

UAASKA-04FZj

001

8,000

3.7/2.2

202

25P5

05

UAASKA-06FZj

002

8,000

5.5/3.7

178

27P5

06

UAASKA-08FZj

003

8,000

7.5/5.5

164

2011

07

UAASKA-11FZj

004

6,000

11/7.5

176

2015

08

UAASKA-15FZj

005

6,000

15/11

164

2018

09

UAASKA-19FZj

006

6,000

18.5/15

148

2022

0A

UAASKA-22FZj

007

6,000

22/18.5

143

2030

0B

UAASKJ-30FZj

008

4,500

30/22

164

2037

0C

UAASKJ-37FZj

009

4,500

37/30

148

Winding

selection

25P5

05

UAASKB-06FZj

062

6,000 (1,500)

5.5/3.7

178

selection

27P5

06

UAASKB-08FZj

063

6,000 (1,500)

7.5/5.5

164

2011

07

UAASKB-11FZj

064

6,000 (1,500)

11/7.5

176

2015

08

UAASKB-15FZj

065

4,800 (1,000)

15/11

164

2018

09

UAASKB-19FZj

066

4,800 (1,000)

18.5/15

148

2022

0A

UAASKB-22FZj

067

4,800 (1,000)

22/18.5

143

2030

0B

UAASKB-30FZj

068

4,800 (1,000)

30/20

180

400 V

Standard

45P5

25

UAASKA-06FZjOOE

102

8,000

5.5/3.7

178

47P5

26

UAASKA-08FZjOOE

103

8,000

7.5/5.5

164

4011

27

UAASKA-11FZjOOE

104

6,000

11/7.5

176

4015

28

UAASKA-15FZjOOE

105

6,000

15/11

164

4018

29

UAASKA-19FZjOOE

106

6,000

18.5/15

148

4022

2A

UAASKA-22FZjOOE

107

6,000

22/18.5

143

4030

2B

UAASKJ-30FZjOOE

108

4,500

30/22

164

4037

2C

UAASKJ-37FZjOOE

109

4,500

37/30

148

4045

2D

UAASKJ-45FZjOOE

10A

4,500

45/37

146

Winding

selection

45P5

25

UAASKB-06FZjOOE

162

6,000 (1,500)

5.5/3.7

178

selection

47P5

26

UAASKB-08FZjOOE

163

6,000 (1,500)

7.5/5.5

164

4011

27

UAASKB-11FZjOOE

164

6,000 (1,500)

11/7.5

176

4015

28

UAASKB-15FZjOOE

165

4,800 (1,000)

15/11

164

4018

29

UAASKB-19FZjOOE

166

4,800 (1,000)

18.5/15

148

4022

2A

UAASKB-22FZjOOE

167

4,800 (1,000)

22/18.5

143

4030

2B

UAASKB-30FZjOOE

168

4,800 (1,000)

30/20

180

Note: Values in parentheses are the maximum speed (min

−1

) of the low-speed windings.

The maximum value of the load factor meter = (30-min rated output x 120%)/(continuous rated output) (%)

6

IMPORTANT