Control Signals

4 -20

4.7 Encoder Pulse Output Circuit

Phase A, B, and C (origin) signals are output from the motor encoder.
An asterisk indicates a reversed signal.
The output signals have the following specifications and can be used for position feedback.

J

Signal Configuration

90° phase-difference, two-phase pulse (A and B), and marker pulse (C)

J

Output Circuit Configuration

The output circuit is a line receiver with RS-422A specifications. Use a line receiver with specifications

matching the RS-422A specifications for signal exchange as shown in the following connection example.

Phase A

Phase B

Phase C

Output line driver

SN75174

Receiver circuit (prepared by user)

Phase A

Phase B

Phase C

Use a line receiver matching

EIA RS-422A standards,

such as the SN75175.

indicates shielded twisted-pair wires.

13

14

15

16

11

12

17

P

P

P

P

Inverter

R

T

R

T

R

T

C

T

C

T

C

T

R

T:

51 to 200Ω

C

T:

47 to 200

P

F

PAO

*PAO

PBO

*PBO

PCO

*PCO

1 CN

Fig 4.5

Encoder Pulse Output Circuit

J

Output Phase

Phase A

(PAO)

Phase B

(PBO)

Phase C

(PCO)

Phase A

(PAO)

Phase B

(PBO)

Phase C

(PCO)

(a) Forward

(b) Reverse

90°

90°

Fig 4.6

Output Phase