2 winding selection motor standard connections – Yaskawa Varispeed 626M5 User Manual

Page 126

Advertising
background image

7.2 Winding Selection Motor Standard Connections

7 -3

7.2 Winding Selection Motor Standard Connections

As shown in the following diagram, this system requires winding selection signals in addition to speed refer-

ence signals such as FWD and REV. In winding selection, a special magnetic contactor is used that can operate

directly from the Inverter.

3MCCB

R

S

T

1MCCB

1MC

L

P/

N/

VS−656MR5

R/L1

S/L2
T/L3

P1

N1

5CN

P1

N1

51CN

VS−626M5

r
t

2MCCB

2MC

A1/r
A2/t

1CN

P/

N/

3CN

52CN

2CN

+5V

0V

4,5,6

1,2,3

THSA

THSB

SS

8

7

9

1

2
3
4
5
6
7
8
9

11

12
10

PG

TS

P

PA

*PA

PB

*PB

PC

*PC

16
17
18
19

14
15

P

P

P

PAO

*PAO

PBO

*PBO

PCO

*PCO

13
14
15
16
11

12

P

P

P

SS 17

1CN

TLL(INC)
SSC(SV)

19,20,21

22,23
24,25

EXTCOM0

*

2

24VCOM

0VCOM

6CN

6
7
8

9

10
11
12

RDY

EMG
FWD

REV
TLH

13
14

5

15
16
17

18

RST
CHW
DAS

PPI
ORT

LGR

MGR

3
4

2

33
34

35

SCOM
0V

SS

ZSPD

36
37

38
39

40

46

41

TDET
TLE
ORG
ORE
CHWE

TALM

FLTL

SDET

AGR

42 COM1

43
44
45

FLT

26
27
28
29

FC0
FC1

FC2
FC3

30 COM2

BCD

BIN

1

1

2

2

4

4

8

8

1
2

4

8

P

r1

t1

IM

X
Y
Z

r1
t1

U

V

2CN

10
20
40
80

100

200
400
800

10
20
40
80

16
32
64

128

256
512

1024

2048

EXTCOM

*

2

24VCOM

0VCOM

31
32
33
19
20
21
22

23

24

25

26
27
28
29
30

D1

D2
D3
D4

D5

D6

D7

D8

D9

D10

D11

D12

6CN

47

48

49

50

SM

0V

0V

LM

U/T1

V/T2

W/T3

+24 V

CC

CA1
CA2

10

11
12
13

17

18
2

4

6

13
14

15

16

9

11

7

W

Z1
Z2

Z3

SM

LM

3-phase

200 VAC

*

1

1-phase

200 VAC

Special bus bar

P1N1 power

supply cable

Flat cable

Not used

Digital

Operator

(optional)

Ground to 100 Ω or less.

Not used

MCCB: Wiring circuit breaker

MC: Magnetic contactor

L: AC reactor

24-V external

power supply

*

3

Speed reference

I/O card

3-phase 200 VAC

*

1

Magnetic contactor

for winding selection

Motor

Cooling fan

Ground to 100 Ω or less.

Motor encoder

signal output

12-bit digital

reference

3-digit 2-digit

*

3

24-V external

power supply

*1

In the 400-V class, 3-phase 400 VAC is used.

*2

6CN EXTCOM0 and 1CN EXTCOM are isolated inter-
nally.

*3

Sequence input common is the external common con-
tact.

indicates shielded twisted-pair cable.

Fig 7.1

Standard Connections Diagram (for 200 V Class Winding Selection Motor)

7

Advertising
This manual is related to the following products: