10.1 User Constants

10-7

Table 10.1

User Constants (continued)

Con-

stant

No.

Name

Explanation

Change

*

1

Unit Standard

Setting

Upper

Limit/

Lower

Limit

C1 60

Magnetic Pole
Positioning
Value

*

6

Adjusts the position of the magnetic pole. Sets the difference between the

magnetic position and the encoder origin signal using the electrical angle

(360_ el = 8192). Set the C1-60 value on the terminal box.

No

4096

8191

C1-60

Value

*

6

(360_ el = 8192). Set the C1-60 value on the terminal box.
When the setting has changed, turn the control power supply OFF then

ON again.

No

---

4096

−8192

C1 61

Phase-C Pulse

Width

*

6

Sets the pulse width of the motor encoder origin signal (phase C). Set the

C1-61 value listed on the terminal box.

No

Pulse

7

100

C1-61

When the setting has changed, turn the control power supply OFF then

ON again.

No

Pulse

7

0

*1.

Change (change during operation) column: Indicates whether the constant can be changed during inverter operation.

Yes: Constant can be changed during inverter operation; No: Constant cannot be changed during inverter operation

*2. This constant is enabled for stand-alone drives (M5A) only. Do not change the set value for NC system s (M5N).
*3. Connector pin numbers are for stand-alone drives.
*4. In signal selection descriptions, 0 stands for “

” and 1 for “

.”

*5. This function is available in the following software.

VSM200XXX: VSM200112 or later

*6. Constants only for IPM motors (with syncs using flush-type permanent magnets). C1-60 and C1-61 are not displayed when the

software for controlling an induction motor is used.