15.4 Interface Design

15 -19

15.4 Interface Design

This section explains the interface design for the signals.

15.4.1 Sequence Input Signals

Among the input signals, 12-bit digital references (1CN) and sequence input signals (6CN), which control

the operation status of forward rotations, reverse rotations, and torque limits, etc., can be used in common

with the relay contacts and transistor switches, as shown in Fig. 15.20. Also, the signal circuit common

can be selected from the 0 V common, which uses the Inverter power supply, the 24-V common, or the

external common, which uses a separate 24-V power supply (20 to 26 V). The wiring differs depending

on the input method, so refer to Fig. 15.21 to perform the wiring correctly. Also, the 1CN common and

6CN common are isolated, so each common can be selected independently. For signal details, refer to 4.1.4

Details on Sequence Input Signals.

PLC

Inverter

Relay Output
Module

(a) Relay Contact

Forward
rotation

Reverse
rotation

0 V

SS

Relay contact capacity
35 VDC min.
Rated current 100 mA min.

PLC

Inverter

Transistor Output
Module

Forward
rotation

Reverse
rotation

0 V

SS

Voltage resistance 35 VDC min.
Rated current 100 mA min.

(b) Transistor (Open Collector)

Fig 15.20 Operation Signals Connection Examples

15