3 multi-step speed operation combined with plc, Appendix – Yaskawa Varispeed 626M5 User Manual

Page 300

Advertising
background image

Appendix

15.6.3 Multi-step Speed Operation Combined with PLC

15 -28

15.6.3 Multi-step Speed Operation Combined with PLC

As shown in Fig. 15.31, this is a multi-step speed operation to a maximum of eight speeds using internal

speed settings by changing the digital speed reference settings. This method is effective when performing

operations by repeating speed patterns that have been set beforehand, such as transfer machines and other

special hole-boring equipment. The speed references are set internally, so there is no effect from speed

reference offset and noise. For multi-step speed operations, select internal speed settings using the control

constant C1-37 (SEL2) settings. For details, refer to 4.3 Using a 12-bit Digital Speed Reference.

3MCCB

Special busbar

R

S

T

1MCCB 1MC

L

P/

N/

VS−656MR5

R/L1

S/L2
T/L3

P1

N1

5CN

P1

N1

51CN

VS−626M5

1-phase
200 VAC

r
t

2MCCB

2MC

A1/r
A2/t

Not used

1CN

P/

N/

Flat cable

3CN

P1N1 power supply
cable

Not used

52CN

Motor

Cooling fan

U

V

IM

2CN

+5V

0V

4,5,6

1,2,3

THSA

THSB

SS

8

7

9

1

2
3

4
5
6

7

8
9

11

12

10

PG

TS

P

PA

:

PA

PB

:

PB

PLC

:

PLC

16
17
18
19

14
15

P

P

P

TLL(INC)
SSC(SV)

19,20,21

22,23
24,25

EXTCOM0*

2

24VCOM

0VCOM

Output Module

*

3

6CN

6
7
8

9

10
11
12

RDY

EMG
FWD

REV
TLH

13
14

5

15
16
17

18

RST
CHW
DAS
PPI
ORT
LGR

MGR

33
34

35

ZSPD

36

37
38
39
40

42

TDET
TLE
ORG
ORE
CHWE
COM1

SDET

AGR

43
44
45

FLT

26
27
28
29

FC0
FC1

FC2
FC3

30 COM2

I/O Card

P

3-phase
200 VAC*

1

41

46

FLTL
TALM

W

Z1
Z2
Z3

External 24 V
power supply

Input Module

LM

SM Speedometer

Load meter

Encoder Interface

PAO

:

PAO

PBO

:

PBO

PLCO

:

PLCO

13
14
15
16
11

12

SS 17

1CN

P

P

P

Output module

External 24 V
power supply

U/T1

V/T2

W/T3

Digital Operator
(optional)

6CN

SM 47

0V 48

LM 50

0V 49

D1
D2
D3
D4
D5
D6

19
20
21
22
23

24

D7 25

0VCOM 33

24VCOM 32

EXTCOM 31

D8
D9

D10

D11

26
27
28
29

D12 30

3
4

2

SCOM
0V

SS

3-phase
200 VAC*

1

(Ground to 100 Ω

or less.)

indicates shielded twisted-
pair cable.

*1

400-V class: 3-phase 400 VAC

*

2

EXTCOM0 on 6CN and EXTCOM

on 1CN are isolated internally.

*

3

Connection when sequence input

common is an external common.

(Ground to 100 Ω

or less.)

MCCB: Molded Case Circuit Breaker
MC:

Magnetic Contactor

L:

AC reactor

PC

PC

*

2

*

3

Fig 15.31 Multi-step Speed Operation Using Internal Speed Settings

15