Ratings and specifications, Dimensions – Yaskawa Varispeed 626M5 User Manual

Page 251

Advertising
background image

14.3 Options and Peripheral Units

14 -47

14.3.3 Magnetic Contactor Specifications for Winding Selection

This section explains the specifications for the winding selection magnetic contactor.

J

Ratings and Specifications

The standard specifications are shown in the following table.

Table 14.19 Standard Specifications

Type

*1

Standard

HV-75AP4

HV-150AP4

HV-200AP4

Type

*1

IPM Motor

*

2

HV-75BP4

HV-150BP4

HV-200BP4

Contact

Main contact: 3NO3NC, auxiliary contact: 1NO

Rated Insulation Voltage

600 V

Rated Applying Cur-

Continuous

75A

150A

200A

Rated Applying Cur-

rent

30 minutes

*

3

87A

175A

226A

Breaking Current Ca-

220 V

200A

400A

400A

Breaking Current Ca

pacity

440 V

150A

300A

300A

Open/Close Frequency

600 times/hr

Mechanical Duration of Life

5 million times

Control Magnetic Coil Rating

200 V 50/60 Hz, 220 V 50/60 Hz, 230 V 60 Hz

Mass

lb (kg)

2.5 kg (5.51 lb)

5.0 kg (11 lb)

5.0 kg (11 lb)

Ambient Temperature

−10 to 55°C (14 to 131°F)

Humidity

10 to 95% (non-condensing)

Applicable Inverter

200 V class

5 HP to 20 HP

(3.7 kW to 15 kW)

25 HP to 40 HP

(18.5 kW to 30 kW)

50 HP (37 kW)

Applicable Inverter

Capacity

400 V class

5 HP to 20 HP

(3.7 kW to 15 kW)

25 HP to 40 HP

(18.5 kW to 30 kW)

50 HP to 60 HP

(37 kW to 45 kW)

* 1. Models with safety covers are as follows: HV-

AP4S and HV-

BP4S.

* 2. IPM motors are the standard models with the short circuit bar removed.
* 3. A dwell time of 1 hour or more is required after applying power supply for 30 minutes.

J

Dimensions

The dimensions are shown below in mm (inches).

85 (3.35)

97 (3.82)

65 (2.56)

Main Circuit Terminals (M5)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

4-M6
Mounting
Holes

Control Circuit
Terminals (M4)

145 (5.71)
160 (6.3)

107

(4.21)

115

(4.53)

1

7

2

8

3

9

4

10

5

11

6

12

22 (0.87)

170 (6.69)

164

(6.46)

148

(5.83)

34 (1.34)

192 (7.56)

34 (1.34)

64 (2.52)

34 (1.34)

64 (2.52)

107 (4.21)

(a) Model HV-75jP4

(b) Models HV-150jP4, HV-200jP4

4-M6
Mounting
Holes

Control Circuit Terminals (M4)

Main Circuit
Terminals (M8)

22 (0.87)

22 (0.87)

Fig 14.16 Dimensions

14

Advertising
This manual is related to the following products: