Control Signals

4.4.4 Details on Sequence Output Signals

4 -16

J

FLT (Fault Bit Signal)

Connector number: 6CN

Pin numbers:

43
44

45

D

The motor current will be shut off instantly when the protective circuit operates for overcurrent or over-

load protection and the motor will coast to a stop. The FLT signal will be output when the current is

shut off.

D

The FLT relay is of SPDT contact construction and operates together with the protective circuit.

D

Turn OFF the FWD, REV or ORT signal while the FLT signal is output and then display the fault at

the host system.

D

The fault number is displayed when the FLTL is output. Refer to the fault number.

D

For the relationship between the FLT and RST signals, refer to the RST signal in 4.1.4 Details on Se-

quence Input Signals.

J

FC0 to FC3 (Fault Code Signals 0 to 3)

Connector number: 6CN

Pin numbers:

26

27

28

30

29

D

A fault code signal is output to provide the details of the operation of the protective function.

D

Refer to tables 12.1 and 12.2 for the details of fault codes.