Yaskawa Varispeed 626M5 User Manual

Page 213

Advertising
background image

14.1 Drives

14 -9

Model CIMR-M5j

*

3

CIMR-MR5j

*

3

45P5

47P5

4011

4015

4018

4022

4030

Ambient Temperature

0°C to 55°C (32°F to 131°F) (not frozen)

er

n

Heatsink Intake Air Temperature

0°C to 45°C (32°F to 113°F)

rolle

r

mon

Storage Temperature

*6

−20°C to 60°C (−4°F to 140°F)

ontr

o

C

om

m

Humidity

90% or less (non-condensing)

C

o

C

o

Location

Indoor (protected from corrosive gases and dust), elevation: 1000 m (3280 ft) or less

Vibration

9.8 m/s

2

(1G) at 10 to less than 20 Hz, up to 2 m / s

2

(0.2G) at 20 to 50 Hz

Protective Structure

IEC IP00

(Protected so that parts of the human body cannot reach electrically charged parts from the front)

* 1. UAASKB-30FZ***E 30/20 kW is 20 minutes (50%ED)/Continuous rated value.
* 2. Rated output power is guaranteed when input voltage is three-phase, 400 V (50/60 Hz), 440 V (50/60 Hz), 460 V (60 Hz).

If input voltage is lower than 400 V, rated output power is not guaranteed.

* 3. A: For stand-alone drive system N: for NC system
* 4. Dimensions of External Heatsink Cooling Type. Refer to 14.1.3 Dimensions for Open Chassis Type.
* 5. An AC reactor is required between Converter and main circuit power supply.
* 6. Temperature during shipping.