3.4.3 Control Signal Functions

3-30

Table 3.13

Control Circuit Signals (6CN)

Connector

Signal

No.

Function

Signal Level

Related Constants

+15V

1

+15V output

+15V Load current: 10mA or less

SS

2

Shield (0V)

C1-26 10 C1-38 bit 5

SCOM

3

Analog speed reference input

0 to ±10V

(Input impedance: 50kΩ)

C1-26, 10, C1-38 bit 5
C1-11, 12

0V

4

Analog speed reference 0V

DAS

5

Digital/analog speed reference

selection

C1-36 bit 7

RDY

6

Operation ready

Selected when C1-37 bit 2=0

EMG2

6

Emergency stop 2

Selected when C1-37 bit 2=1

EMG

7

Emergency stop

FWD

8

Forward run

REV

9

Reverse run

TLH

10

Torque limit H

Selected when C1-36 bit 2=0
C1-26, C1-38 bit 2

TLL

11

Torque limit L

Selected when C1-36 bit 1, 0=00

INC

11

Incremental

Selected when C1-36 bit 1, 0=10

SSC

12

Soft start cancel

Selected when C1-36 bit 3=0

SV

12

Servo mode

24VDC

Selected when C1-36 bit 3=1

RST

13

Fault reset

24VDC
Current when closed: 5mA

CHW

14

Winding selection

Current when closed: 5mA

PPI

15

P control/PI control selection

Selected when C1-36 bit 4=0

ORT

16

Orientation

Selected when C1-40 bit 3=0
C1-39 bit 0

NCORT

16

NC orientation

Selected when C1-40 bit 3=1

LGR

17

L gear selection

C1 27 28 29

MGR

18

M gear selection

C1-27, 28, 29

EXT-

COM0

19 to 21 Sequence input signal power sup-

ply common

6CN

24VCOM

22, 23

Sequence input signal power sup-

ply 24V

0VCOM

24, 25

Sequence input signal power sup-

ply 0V

FC0

26

Fault code 0

FC1

27

Fault code 1

Open-collector output

FC2

28

Fault code 2

p

p

Exclusive-use for 24VDC

FC3

29

Fault code 3

Exclusive use for 24VDC
Load current: 50mA or less

COM2

30

Fault code signal common

Load current: 50mA or less

ZSPD

33

Zero-speed

C1-19

AGR

34

Speed agree

C1-20, C1-38 bit 6

SDET

35

Speed detection

C1-21, C1-22, C1-40 bit 2

TDET

36

Torque detection

C1-23

TLE

37

Torque limit

Open-collector output

ORG

38

Load origin

p

p

Exclusive-use for 24VDC

ORE

39

Orientation completion

Exclusive use for 24VDC
Load current: 50mA or less

C2-09, 10 or C3-09, 10

CHWE

40

Winding selection completion

Load current: 50mA or less

FLTL

41

Fault (OFF at fault)

TALM

46

Minor fault

COM1

42

Sequence output signal common

FLTNO

43

Fault contact output

Relay contact output
Exclusive-use for 24VDC

FLTNC

44

Fault contact output
Closed between 43 and 45 at fault

Exclusive-use for 24VDC
Load current: 1A or less

FLTCOM

45

Open between 44 and 45 at fault

Minimum permissible load: 10 mA

(as reference value)

SM

47

Speedometer output

0 to +10V Load current: 2mA or less

C1-16, 54

0V

48

0V for speedometer

LM

50

Load ratio meter output

0 to +10V Load current: 2mA or less

C1-17, 54, 18, C1-40 bit 4
C1 38 bit 1 0

0V

49

0V for load ratio meter

C1-38 bit 1, 0
C1-38 bit 7

Note: The 5CN connector is for M5A models for stand-alone drive.