3 using a 12-bit digital speed reference – Yaskawa Varispeed 626M5 User Manual

Page 85

Advertising
background image

Control Signals

4 -10

4.3 Using a 12-bit Digital Speed Reference

This section provides information on using a 12-bit digital speed reference input (for stand-alone drive systems

M5A only).

J

D1 through D12 (12-bit Digital References 1 through 12)

Connector number: 1CN
Pin numbers: 19 through 30
12-bit Digital Reference Signal Function Selection: 1CN-19 to 1CN-30 will be the 12-bit Digital Refer-

ence if bit 07 of the C1-36 selection signals (SEL1) is turned OFF.

Bit

7

C1−36

D

Bit 7 is used for internal speed or digital speed settings.

D

It is possible to select 12-bit binary, 2-digit BCD, 3-digit BCD, or internal speed setting for digital

speed references. Speed references are factory-set to 12-bit binary.

D

The setting method can be selected using bits 6 and 7 of selection signal C1-37 (SEL2).

Bit

7 6

C1−37

D

Selecting the Speed Setting

6CN-5, 19

C1-37 (SEL2)

Speed Selection

DAS

Bit 7

Bit 6

OFF

---

---

Analog speed

ON

OFF

OFF

2-digit BCD

OFF

ON

Binary

ON

OFF

3-digit BCD

ON

ON

Internal speed

D

The DAS signal can be switched only when the system is not in operation.

D

If the binary, BCD, or internal speed setting method is selected, the forward or reverse rotation of the

motor is selected with the external FWD or REV relay signal.

Internal Speed Setting

Number of speed settings: 8

Speed set value: Input into C1-41 through C1-48 the percentages based on the rated speed set for C1-26

(S100). Set range: 0.00 to 100.00

Control Constant

Signal

Name

1CN Input

Pin Number

C1-41

SPD1

Internal speed setting 1

D1

19

C1-42

SPD2

Internal speed setting 2

D2

20

C1-43

SPD3

Internal speed setting 3

D3

21

C1-44

SPD4

Internal speed setting 4

D4

22

C1-45

SPD5

Internal speed setting 5

D5

23

C1-46

SPD6

Internal speed setting 6

D6

24

C1-47

SPD7

Internal speed setting 7

D7

25

C1-48

SPD8

Internal speed setting 8

D8

26

D

If two or more speed selection signals (D1 through D8) are turned ON at the same time, the smaller

selection signal number will be enabled. (For example, if D2 and D5 are turned ON simultaneously,

D2 will be enabled.)

D

If all speed selection signals are OFF, the speed references are treated as 0.

D

No speed reference values in C1-41 through C1-48 can be changed while the system is in operation.

4

Advertising
This manual is related to the following products: