CPS6000-M2 Installation Guide H5694720

Issue 8 January 2008

108

Ringer Status LEDs

LED

Condition

Normal operation: No alarms, inputs and outputs are in their normal range,
communicating with the system controller.
Note: In a redundant system, one ringer is in “Normal Operation” and the second
unit is in “Standby (on-line spare)”, see below.

Unpowered: No input or output voltage present.
; Remove and reinsert ringer.
; Check input voltage with a voltmeter, if input voltage is present, replace

ringer.

; Check output bus voltage with a voltmeter, if output bus voltage is present,

replace ringer.

Startup: The power unit initializing, but has not started delivering power.
; Wait for initialization to complete.
Lamp Test: The controller has initiated a Lamp Test operation

Standby (on-line spare): The ringer is okay and has input, but is an on-line
spare and is not delivering power. The unit will switch to “normal operation” if
the other ringer fails.
Standby (remote): The ringer is okay and has input, but has been placed in
Standby by the controller and is not delivering power.

External Fault:
• Ring Return not terminated
• Output limited – excessive output load
• Output limited – excessive temperature

Internal Fault:
• Thermal shutdown
• Ringer failure

Communication Fail: Blinks to indicate the ringer is not communicating with a
system controller.
; Remove and reinsert ringer. If fault remains and other units are

communicating correctly, replace ringer.