SAS Link and Transport Layer Test Suite v0.13
Test 7.1.3 - Link Reset – HARD_RESET Received
Purpose: To determine that the DUT properly handles a received HARD_RESET.
References:
7.2.5.8, 7.9.1 SAS Standard
Resource Requirements: SAS Protocol Analyzer and Generator
Revision History: September 7, 2004
Test Setup: The DUT and the Testing Station are physically connected.
Test Procedure:
• The Testing Station should transmit COMINT to start a Phy Reset sequence with the DUT.
• The Testing Station should complete a Phy Reset sequence with the DUT.
• Once the Phy reset sequence between the DUT and the Testing Station are complete, the Testing
Station should transmit 6 consecutive HARD_RESET primitives. This must occur before the Identify
sequence is complete.
Observable Results:
• Verify that the DUT transmits COMINIT upon receiving the HARD_RESET primitives from the
Testing Station.