SAS Link and Transport Layer Test Suite v0.13

Test 7.2.2 - Connections – 2 SOAF Received

Purpose: To determine that the DUT properly handles received 2 SOAF primitives.

References:

7.2.5.11 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator

Revision History: September 7, 2004

Test Setup: The DUT and the Testing Station are physically connected.


Test Procedure (Initiators):

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is an initiator the Testing Station should transmit an Identify Address
frame indicating that it is a target.

• Wait for the DUT to transmit an Open Address frame to the Testing Station. The Testing Station

should transmit OPEN_ACCEPT followed by RRDY. Allow the DUT to transmit a frame and close
the connection.

• The Testing Station should transmit the following to the DUT

o SOAF primitive
o the first 4 dwords of an OpenAddress frame
o complete Open Address frame starting with SOAF.

• Wait for the DUT to transmit OPEN_ACCEPT and RRDY.


Observable Results:

Verify that the DUT responded to the received, complete Open Address frame with OPEN_ACCEPT.