The University of New Hampshire

InterOperability Laboratory



Serial Attached SCSI Consortium

47

SAS Link and Transport Layer Test Suite v0.13

Test 9.5.2 - SSP RESPONSE IU – SENSE DATA PRESENT

Purpose: To determine that the DUT, an SSP Target port, properly sets the DATAPRES field to NO_DATA if a
command completes without sense data to return.

References:

9.2.2.5.1 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator.

Revision History: September 27, 2004

Test Setup: The DUT and the Testing Station are physically connected. The DUT is not powered on.

Test Procedure (SSP Target):

• Power on the DUT.

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is a SAS Initiator.

• The Testing Station should open an SSP connection to the DUT and transmit a SCSI Test Unit Ready

command to the DUT. This should be the first command received by the DUT since power on. Close
the connection

• Allow the DUT to open an SSP connection to the Testing Station and transmit a SCSI response frame

to the received command.

Observable Results: Verify that the DUT sets the DATAPRES field to SENSE_DATA and the command
completes with sense data to return when the command finishes with status CHECK CONDITION.