SAS Link and Transport Layer Test Suite v0.13

Test 7.1.2 - Link Reset – Ignore Additional Identify Recieved

Purpose: To determine that the DUT will ignore an Identify frame received after a valid Identify has already been
received.

References:

7.9.1 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator

Revision History: September 7, 2004

Test Setup: The DUT and the Testing Station are physically connected.


Test Procedure:

• The Testing Station should transmit COMINT to start a Phy Reset sequence with the DUT.

• The Testing Station should complete a Phy Reset sequence with the DUT.

• Once the Phy reset sequence between the DUT and the Testing Station are complete, the Testing

Station should transmit valid SAS primitives or SAS Idle. The Testing Station should transmit 2 valid
Identify Address Frames each with a different SAS address.



Observable Results:

• Verify that the DUT ignores the second received Identify Address Frame and does not transmit

COMINIT.

• Verify that the DUT does not attempt to open a connection to the address in the second Identify

Address frame.