SAS Link and Transport Layer Test Suite v0.13

Test 9.2.1 - SSP Command IU – TAG

Purpose: To determine that the DUT properly sets the TAG field.

References:

9.2.1 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator. SAS Target with 2 LUNs within the same SSP
Target Port. If the DUT is an initiator, it will need to have software capable of generating SCSI traffic.

Revision History: September 23, 2004

Test Setup: The DUT and the Testing Station are physically connected. The SAS Initiator DUT is attached to the
SAS Target through a SAS Protocol analyzer.

Test Procedure (SSP Initiators):

• Allow the DUT to open a connection to the attached SAS Target. Observe commands from the DUT to

each LUN on the target.


Observable Results: If the DUT is an initiator, verify that the TAG field is unique for commands to different LUNs
no the SSP target port.