Teledyne LeCroy SAS Verification Test Descriptions User Manual
Page 93
The University of New Hampshire
InterOperability Laboratory
Serial Attached SCSI Consortium
92
SAS Link and Transport Layer Test Suite v0.13
Test 9.2.1 - SSP Command IU – TAG
Purpose: To determine that the DUT properly sets the TAG field.
References:
9.2.1 SAS Standard
Resource Requirements: SAS Protocol Analyzer and Generator. SAS Target with 2 LUNs within the same SSP
Target Port. If the DUT is an initiator, it will need to have software capable of generating SCSI traffic.
Revision History: September 23, 2004
Test Setup: The DUT and the Testing Station are physically connected. The SAS Initiator DUT is attached to the
SAS Target through a SAS Protocol analyzer.
Test Procedure (SSP Initiators):
• Allow the DUT to open a connection to the attached SAS Target. Observe commands from the DUT to
each LUN on the target.
Observable Results: If the DUT is an initiator, verify that the TAG field is unique for commands to different LUNs
no the SSP target port.