The University of New Hampshire
InterOperability Laboratory
Serial Attached SCSI Consortium
20
SAS Link and Transport Layer Test Suite v0.13
Test 7.3.1 - SSP_Frames - Interlocked Frame
Purpose: To determine that the DUT handles interlocked frames properly.
References:
7.16.3, 7.16.5 SAS Standard
Resource Requirements: SAS Protocol Analyzer and Generator
Revision History: September 13, 2004
Test Setup: The DUT and the Testing Station are physically connected. This test is only applicable to targets.
Test Procedure (Targets):
• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence
with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is an initiator.
• The Testing Station should open a SSP connection to the DUT and transmit a SCSI_INQUIRY
command.
• Wait for the DUT to transmit ACK followed by SCSI Response.
Observable Results: Verify that upon receiving the INQUIRY command, the DUT transmitted ACK before
transmitting any other frame to the Testing Station.