The University of New Hampshire

InterOperability Laboratory



Serial Attached SCSI Consortium

20

SAS Link and Transport Layer Test Suite v0.13

Test 7.3.1 - SSP_Frames - Interlocked Frame

Purpose: To determine that the DUT handles interlocked frames properly.

References:

7.16.3, 7.16.5 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator

Revision History: September 13, 2004

Test Setup: The DUT and the Testing Station are physically connected. This test is only applicable to targets.

Test Procedure (Targets):

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is an initiator.

• The Testing Station should open a SSP connection to the DUT and transmit a SCSI_INQUIRY

command.

• Wait for the DUT to transmit ACK followed by SCSI Response.


Observable Results: Verify that upon receiving the INQUIRY command, the DUT transmitted ACK before
transmitting any other frame to the Testing Station.