The University of New Hampshire

InterOperability Laboratory



Serial Attached SCSI Consortium

26

SAS Link and Transport Layer Test Suite v0.13

Test 7.4.3 - Closing SSP Connections – DONE (CREDIT TIMEOUT)

Purpose: To determine that the DUT properly responds when RRDY has not been received for an impending
transaction.

References:

7.16.6 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator

Revision History: September 13, 2004

Test Setup: The DUT and the Testing Station are physically connected.


Test Procedure (Targets):

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is an initiator.

• The Testing Station should open an SSP connection to the DUT.

• Wait for the DUT to transmit OPEN_ACCEPT and RRDY. The Testing Station should transmit a

SCSI INQUIRY command to the DUT, then close the connection.

• Wait for the DUT to open an SSP connection to the Testing Station. The Testing Station should not

transmit RRDY to grant credit for the DUT to transmit a SCSI Response to the Testing Station.


Observable Results: Verify that the DUT transmitted DONE (CREDIT TIMEOUT) within 1 msec of opening the
SSP connection.