Teledyne LeCroy SAS Verification Test Descriptions User Manual

Page 60

Advertising
background image

The University of New Hampshire

InterOperability Laboratory



Serial Attached SCSI Consortium

59

SAS Link and Transport Layer Test Suite v0.13

Test 10.1.5 - SCSI CDB – MODE SELECT

Purpose: To determine that the DUT, an SSP Target port, properly handles a MODE SELECT command.

References:

SPC-3 6.7

Resource Requirements: SAS Protocol Analyzer and Generator.

Revision History: February 8, 2005

Test Setup: The DUT and the Testing Station are physically connected. The DUT is not powered on .

Test Procedure (SSP Target):

• Power on the DUT.

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is a SAS Initiator.

• The Testing Station should open an SSP connection to the DUT and transmit a SCSI MODE

SENSE(6) command to the DUT with the PAGE CODE field set 02h and the SUBPAGE CODE set to
00h. This will request the Disconnect-Reconnect Mode Page. Close the connection

• Allow the DUT to open an SSP connection and transmit DATA, containing standard Disconnect

Reconnect Mode Parameters, and RESPONSE frames to the received command.

• The Testing Station should open an SSP connection to the DUT and transmit a SCSI MODE

SELECT(6) command to the DUT with the PF bit set to 1, the SP bit set to 1. Close the connection.

• Allow the DUT to open an SSP connection to transmit an XFER_RDY frame.

• The Testing Station should open an SSP connection to the DUT and transmit a DATA frame to the

DUT containing Mode Parameters for the Disconnect Reconnect Mode Page with a new Maximum
Burst Size. Close the connection.

• Allow the DUT to open an SSP connection to transmit a RESPONSE frame.


Observable Results: Verify that the DUT transmits RESPONSE frame indicating that the command completed
with GOOD status.