The University of New Hampshire

InterOperability Laboratory



Serial Attached SCSI Consortium

36

SAS Link and Transport Layer Test Suite v0.13

Test 9.1.3 - SSP Frames Structure – NUMBER OF FILL BYTES

Purpose: To determine that the DUT properly sets the NUMBER OF FILL BYTES field.

References:

9.2.1 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator.

Revision History: September 23, 2004

Test Setup: The DUT and the Testing Station are physically connected.

Test Procedure (SSP Targets):

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is an initiator.

• The Testing Station should open an SSP connection to the DUT. The Testing Station should transmit a

READ command to the DUT.

• Wait for the DUT to open an SSP connection to the Testing Station. Allow the DUT to transmit DATA

and SCSI Response to the Testing Station.

Observable Results: If the DUT is a target, verify that the NUMBER OF FILL BYTES field in the SSP Response
frame is set to 0.