The University of New Hampshire

InterOperability Laboratory



Serial Attached SCSI Consortium

50

SAS Link and Transport Layer Test Suite v0.13

Test 9.6.1 - SSP ERROR HANDLING – Invalid Length

Purpose: To determine that the DUT, an SSP Target port properly handles a command received which is too short
to contain a valid CDB.

References:

9.2.5.1 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator.

Revision History: September 27, 2004

Test Setup: The DUT and the Testing Station are physically connected.

Test Procedure (SSP Target):

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is a SAS Initiator.

• The Testing Station should open an SSP connection to the DUT and transmit a SCSI INQUIRY

command with a too short CDB. Close the connection

• Allow the DUT to open an SSP connection and transmit a SCSI response frame to the received

command and data.

Observable Results: Verify that if the DUT sets the DATAPRES field to RESPONSE_DATA and the RESPONSE
CODE field to INVALD FRAME.