SAS Link and Transport Layer Test Suite v0.13

Test 7.3.4 - SSP Frames - RRDY

Purpose: To determine that the DUT properly grants credit to transit frames using RRDY.

References:

7.16.4 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator

Revision History: September 13, 2004

Test Setup: The DUT and the Testing Station are physically connected.

Test Procedure (Targets):

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is an initiator.

• The Testing Station should open an SSP connection to the DUT.

• Wait for the DUT to transmit OPEN_ACCEPT and RRDY.


Observable Results: Verify that the DUT transmitted RRDY when an SSP connection was opened.