SAS Link and Transport Layer Test Suite v0.13

Test 9.1.1 - SSP Frames Structure – Hashed Address

Purpose: To determine that the DUT properly calculated a hashed destination SAS address based on the sas address
provided in a received Identify Frame.

References:

4.2.3, Annex D SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator. SAS Target.

Revision History: September 23, 2004

Test Setup: The DUT and the Testing Station are physically connected.

Test Procedure (Targets):

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is an initiator. The SAS address provided in the Identify Frame should be
7FFFFFFFFFFFFFFFh.

• The Testing Station should open an SSP connection to the DUT.

• Wait for the DUT to transmit OPEN_ACCEPT and RRDY. The Testing Station should transmit a

SCSI INQUIRY command to the DUT, then close the connection.

• Wait for the DUT to open an SSP connection to the Testing Station. Allow the DUT to transmit a SCSI

Response to the Testing Station.

Observable Results: In each case verify that the DUT transmitted an SSP frame (command or response) with a
hashed destination SAS address of 000000h.