Teledyne LeCroy SAS Verification Test Descriptions User Manual
Page 17
The University of New Hampshire
InterOperability Laboratory
Serial Attached SCSI Consortium
16
SAS Link and Transport Layer Test Suite v0.13
Test 7.2.4 - Connections - OPEN_REJECT Connection Rate Not Supported
Purpose: To determine that the DUT handles errors in OpenAddress frames properly.
References:
7.2.5.11, 7.8.3 Table 74 SAS Standard
Resource Requirements: SAS Protocol Analyzer and Generator
Revision History: September 13, 2004
Test Setup: The DUT and the Testing Station are physically connected.
Test Procedure (Targets):
• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence
with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is an initiator.
• The Testing Station should transmit an OpenAddress frame to the DUT with an invalid connection
rate.
• Wait for the DUT to transmit OPEN_REJECT (Connection rate not supported).
Observable Results: Verify that the DUT responded to the received, complete Open Address frame with
OPEN_REJECT (Connection rate not supported).