Teledyne LeCroy SAS Verification Test Descriptions User Manual
Page 28
The University of New Hampshire
InterOperability Laboratory
Serial Attached SCSI Consortium
27
SAS Link and Transport Layer Test Suite v0.13
Test 7.4.4 - Closing SSP Connections – CLOSE (NORMAL)
Purpose: To determine that the DUT properly responds when CLOSE (NORMAL) is received.
References:
7.12.7, 7.16.6 SAS Standard
Resource Requirements: SAS Protocol Analyzer and Generator
Revision History: September 13, 2004
Test Setup: The DUT and the Testing Station are physically connected.
Test Procedure (Targets):
• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence
with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is an initiator.
• The Testing Station should open an SSP connection to the DUT. Wait for the DUT to transmit
OPEN_ACCEPT. The Testing Station should transmit a CLOSE (NORMAL) primitive to the DUT.
Observable Results: Verify that the DUT transmitted CLOSE (NORMAL) within 1 msec of receiving CLOSE
(NORMAL) from the Testing Station.