Teledyne LeCroy SAS Verification Test Descriptions User Manual
Page 106
The University of New Hampshire
InterOperability Laboratory
Serial Attached SCSI Consortium
105
SAS Link and Transport Layer Test Suite v0.13
Test 7.2.8 - Connections - OPEN_REJECT Bad Destination
Purpose: To determine that the DUT handles errors in OpenAddress frames properly.
References:
7.2.5.11 SAS Standard
Resource Requirements: SAS Protocol Analyzer and Generator
Revision History: February 15, 2005
Test Setup: The DUT and the Testing Station are physically connected. This test is only applicable to SAS
Expanders.
Test Procedure (Expanders only):
• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence
with the DUT. Since the DUT is an expander the Testing Station should transmit an Identify Address
frame indicating that it is an SMP initiator.
• The Testing Station should transmit an SMP OpenAddress frame to the DUT with the destination SAS
address equal to the source SAS Address
• Wait for the DUT to transmit OPEN_REJECT (Bad Destination)
Observable Results: Verify that the DUT responded to the received, complete Open Address frame with
OPEN_REJECT (Bad Destination).