The University of New Hampshire

InterOperability Laboratory



Serial Attached SCSI Consortium

45

SAS Link and Transport Layer Test Suite v0.13

Test 9.4.4 - SSP XFER_RDY IU – WRITE DATA LENGTH

Purpose: To determine that the DUT, an SSP Target port, properly sets the DATA OFFSET field when transmitting
DATA frames.

References:

9.2.2.3 SAS Standard

Resource Requirements: SAS Protocol Analyzer and Generator.

Revision History: February 8, 2005

Test Setup: The DUT and the Testing Station are physically connected. The DUT is not powered on.

Test Procedure (SSP Target):

• Power on the DUT.

• The Testing Station should start and complete a Phy Reset sequence followed by an Identify sequence

with the DUT. Since the DUT is a target the Testing Station should transmit an Identify Address frame
indicating that it is a SAS Initiator.

• The Testing Station should open an SSP connection to the DUT and transmit a SCSI MODE SENSE

command for the Disconnect-Reconnect Mode Page. Close the connection

• Allow the DUT to open an SSP connection to the Testing Station and transmit DATA frame with the

Mode Page Block Descriptor and a SCSI response frame to the received MODE SENSE command.

• The Testing Station should open an SSP connection to the DUT and transmit a SCSI

WRITE_BUFFER command for 2051 bytes. Close the connection

• Allow the DUT to open an SSP connection to the Testing Station and transmit XFER_RDY, DATA,

SCSI response frame to the received command.

Observable Results: Verify that if the DUT sets the WRITE DATA LENGTH field not a value that is not divisible
by four, that this is the last XFER_RDY frame for a command.