InterOperability Laboratory

Gbps for one SNTT. If the DUT supports 3.0 Gbps signaling, it is expected to the same.

10. The Testing Station is then instructed to transmit D.C. Idle for one RCDT. The DUT is

expected to do the same.

11. The Testing Station is the instructed to transmit its Phy Capabilities bits indicating

support for all speeds and SSC settings. The DUT is expected to transmit it's Phy
Capabilities Bits.

Observable Results

Verify that following the last COMWAKE signal transmitted during SNW-3 by the DUT,
there is at least 562294.8 µs of D.C. Idle transmitted by the DUT.

Possible Problems

None.

UNH-IOL