Electrical installation − HighLine/StateLine version

Safety engineering

6

l

103

EDS84DPS424 EN 5.0

X61 − connection of safety system "Safety Option 10"

Pin

Connection

Description

Data

M12, 5−pole pins, A−coded

84DPSO05_5

1

SIA

Safe input, channel A

I

typ

= 45 mA

LOW: −3 ... 5 V
HIGH: 18 ... 30 V
Supply through safely
separated power supply unit
(SELV/PELV).

2

SIB

Safe input, channel, B

5

GI

1. GND potential for SIA/SIB
2. GND potential for the non−safe signalling

output

24 V, max. 0.2 A
short−circuit−proof
Supply through safely
separated power supply unit
(SELV/PELV).
High active

4

24O

24−V voltage supply for the non−safe signalling
output

3

DO1

Non−safe signalling output: "SafeTorqueOff"
with 2−channel request by SIA and SIB

Advertising