Electrical installation − HighLine/StateLine version
Safety engineering
l
103
EDS84DPS424 EN 5.0
X61 − connection of safety system "Safety Option 10"
Pin
Connection
Description
Data
M12, 5−pole pins, A−coded
84DPSO05_5
1
SIA
Safe input, channel A
I
typ
= 45 mA
LOW: −3 ... 5 V
HIGH: 18 ... 30 V
Supply through safely
separated power supply unit
(SELV/PELV).
2
SIB
Safe input, channel, B
5
GI
1. GND potential for SIA/SIB
2. GND potential for the non−safe signalling
output
24 V, max. 0.2 A
short−circuit−proof
Supply through safely
separated power supply unit
(SELV/PELV).
High active
4
24O
24−V voltage supply for the non−safe signalling
output
3
DO1
Non−safe signalling output: "SafeTorqueOff"
with 2−channel request by SIA and SIB