Technical data, Stop – Lenze 8400 protec Manual User Manual

Page 69

Advertising
background image

Technical data

Control terminals

Motor holding brake connection

4

l

69

EDS84DPS424 EN 5.0

Version according to type code: C (DC voltage: cold brake)

X21

Pin / Name

Feature

Rated value

6 / BD1
4 / BD2

Connection of a motor holding brake

Voltage boost for 0.3 s

130 %

Voltage reduction (cold brake) after 0.3 s

65 %
Half−wave rectification with increased ripple

Output voltage
(dependent on mains voltage)

AC 400 V

DC 180 V

AC 500 V

DC 225 V

Max. output power

55 W

Internal switching time

< 1 ms

Time−dependent behaviour

See software manual, chapter holding brake
control / parameterisation

Short−circuit strength

no

Behaviour in case of reset and during
switch−on

Outputs are switched off

Operating frequency

Max. 60/min

(

Stop!

Damage of the devices
A defective motor holding brake or a short circuit on the X21 connection
(motor and built−on accessories) causes internal damage to the device.
Possible consequences:

ƒ

If a defective motor holding brake is connected, the replacement device is
also damaged immediately.

Protective measures:

ƒ

When devices are replaced due to malfunction of the brake control, ensure
that defect−free motor holding brakes are connected.

ƒ

Check whether the motor holding brake and the connecting cable are free
from defects.

ƒ

Replace or repair defective components.