Diagnostics

Display of operating data, diagnostics
Status display via controller LEDs

10

l

160

EDS84DPS424 EN 5.0

Status display: device

Pos.

Colour

State

Description

DRV−RDY

green

on

Controller is ready

blinking

Controller is enabled

ERR

red

on

System error

blinking

Fault is active

off

No fault

24V−S

green

on

24 V voltage is ready

off

24−V voltage is not ready

Brake

yellow

on

Motor holding brake is controlled (released)

off

Motor holding brake is not controlled (applied)

Status display: fieldbus interface

Pos.

Colour

State

Description

BUS−RDY

green

blinking

Communication has been established

on

Communication has been stopped

off

Communication has not been initialised

BUS−ERR

red

fast blinking

Communication error
for PROFINET: Node not recognised

blinking

for PROFINET: Node recognition

on

Communication error

Link−1

yellow

fast blinking

only for PROFINET: Communication is active, telegrams are
transmitted

blinking

Initialisation

Link−2

off

Communication is not active

Status display: Digital signals

Pos.

Colour

State

Description

DI1

yellow

on

DI1 = HIGH

off

DI1 = LOW

DI2

yellow

on

DI2 = HIGH

off

DI2 = LOW

DI3/DO1

yellow

on

DI3/DO1 = HIGH

off

DI3/DO1 = LOW

DI4/DO2

yellow

on

DI4/DO2 = HIGH

off

DI4/DO2 = LOW

DI5

yellow

on

DI5 = HIGH

off

DI5 = LOW

DI6

yellow

on

DI6 = HIGH

off

DI6 = LOW

Advertising